Hand-operated single stamping machine use precautions:
1, before the first use of the machine should be carefully read the manual, and then use. When the equipment is in use, the equipment should be supported on a fixed workbench.
2. Do not put your hand under the upper mold and middle mold to avoid personal injury.
3, the machine can only run in a certain direction (see the arrow of the main shaft), can not be reversed, so as not to damage the parts. Pay special attention to the adjustment of the tablet, do not neglect.

4, before starting, the upper punch rod should be in the rising position and then start. If the upstroke is started in the case of falling, it has just started to enter the molded sheet, at this time because the operation of the machine has not risen, the inertia is small, prone to jacking accidents. (That is, after the upper punch enters the middle die, it "tops" due to the resistance of the pill, so that the machine stops running. Due to the large load, often damaged parts).
5, the handling method after the roof
(1) When the jacking situation is light, rotate the handwheel by hand to make the upstroke pass the "dead point" (but it cannot be reversed, so as not to repeat the feeder, causing more serious jacking).
(2) In severe jacking, loosen the connecting rod locking nut, turn the upper punch rod, make it rise to reduce the pressure, and then turn the handwheel to push the pill out. Then re-adjust the hardness of the pill.
6, in the tablet pressing process must often check the quality of the tablet (tablet weight, hardness, surface finish, etc.), and timely adjustment.