Jul 04, 2024 Leave a message

Failure analysis of pill making machine

1. Decocting electric control board display E1: heating plate temperature protection

Elimination method:

(1) Remove dry pan heating;

(2) Remove heat conductive glue on the temperature control switch (190 ° C) or sensor;

(3) The heating plate is out of the bottom of the pan or burned out, need to replace the heating plate and the bottom of the pan

Experiment 4-1: Disconnect the temperature control switch line and observe the phenomenon.

Hands-on 4-1: Change the heating plate with the bottom of the pan.

2. The electric control board shows E3: (1)15A safety failure (2) thyristor open circuit

Elimination method: check the insurance or replace the medicine electric control board

Hands-on 4-2: Replace the medicine control board

Experiment 4-2: Take out the corresponding pot body safety and observe the phenomenon.

3. The electric control board shows E4: thyristor short circuit.

Elimination method: Replace the medicine electric control board.

4. Decocting electric control board display E5: temperature sensor open circuit (micropressure machine)

Troubleshooting method: Repair the open circuit part, or the plug part.

Experiment 4-3: Disconnect the temperature sensor line and observe the phenomenon.

5. Decocting electric control board shows E6: temperature sensor short circuit (micropressure machine)

Elimination method: Change the temperature sensor or change the electric control board.

Experiment 4-4: Short-circuit the temperature sensor line and observe the phenomenon.

6. The pot is not heated, the heating indicator is not bright: the safety, or the thyristor is bad.

Hands-on 4-3: Change the insurance

7. The pot is not heated, the display light is on: the heating wire is open or the heating plate is burned out.

Elimination method: repair the heating wire or change the heating plate.

Experiment 4-5: Manually disconnect the heating wire and observe the phenomenon

8. Open the main switch, the pot will be heated, the heating indicator light: thyristor short circuit.

Elimination method: change the electric control board.

9. Spare valve drainage is not smooth: the pipeline is blocked with foreign bodies.

Elimination method: dredge ball valve, hexagonal body and connected silicone tube.

Start 4-5: dredge ball valve and hexagonal body.

 

Chinese medicine pill making machine

 

5. Packaging machine fault analysis and elimination

(1) Electric control part

1. Package control panel displays letter OP: open circuit on (down) temperature sensor.

Elimination method:

(1) Repair the open circuit

(2) Replace the heating tube

(3) Sometimes because the basic temperature is too low, there is a false "OP" phenomenon.

Experiment 5-1: Manually disconnect the sensor line and observe the phenomenon.

2. The packaging control panel displays ST: Short circuit on the upper (lower) of the temperature sensor. Note: The resistance value is 0.

Elimination method:

(1) Repair the short circuit part,

(2) Change the heating tube,

Experiment 5-2: Artificial short circuit of sensing line, observation phenomenon.

3. The packaging control panel shows HE(machine before 2004) : open the heating line (lower) of the heating tube

Elimination method:

(1) Repair the open circuit

(2) Change the heating tube,

Experiment 5-3: Manually disconnect the heating wire and observe the phenomenon.

Hands-on 5-1: Change a set of heating tubes.

4. Open the heat sealing and motor rotation, the control board does not show: the micro-switch (outside) is loose and fails.

Elimination method: Adjust the micro switch.

Experiment 5-4: Artificially loosening the microswitch and observing the phenomenon.

5. The power supply is available, the indicator is on, but the drug decocting machine and packaging machine cannot be started: the transformer or transformer insurance (0.5A) or packaging machine insurance (7A) is burned out

Elimination method:

Replace the corresponding fuse or transformer

Hands-on 5-2: How to Change a transformer? Observe the position of the fuse.

6. The heat sealing number is unstable or uncontrollable: the heating tube temperature sensor fails or the power supply interferes

Elimination method:

(1) Replace the heating tube with sensor

(2) Eliminate interference, or increase anti-interference power filter

(2) Packaging

1, packaging night, that is, packaging tape dislocation and appearance deformation, adhesion is not strict resulting in night:

(1) Temperature discomfort

(2) tension discomfort

(3) The working surface of the roller is dirty

(4) Volume pressure

(5) stop ring dislocation mandrel stop ring copper washer does not slip fast

Elimination method:

(1) Re-adjust the upper and lower heat and temperature each time up (down) adjust the temperature 3 to 5 degrees

(2) Re-adjust the upper (lower) shaft tension each time up (lower) adjust the tension 1-2 turns

(3) Clean the roller working surface

(4) Readjust the volume pressure

(5) Remove the foreign body in the mandrel stop ring

Experiment 5-5: How to adjust the heat sealing temperature?

Experiment 5-6: Increase or decrease the volume pressure and observe the phenomenon.

Experiment 5-7: Increase or decrease the spring tension and observe the phenomenon.

Hands-on 5-3: How to adjust spring tension?

2. Knife: (1) insufficient tension (2) bakelite too tight (3) tool shaft dislocation (4) blade aging

Elimination methods: (1) Adjust the tension (2) adjust the bakelite (3) adjust the knife shaft (4) change the blade

Experiment 5-9: Adjust the bakelite too tight or too loose, observe the phenomenon.

Hands-on 5-4: How to adjust the tool shaft dislocation?

(3) Transmission part

1. Cut the sound too loud:

(1) Tension is too tight

(2) Bakelite pine or lack of oil

(3) Blade aging

Elimination methods: (1) Adjust the tension (2) tighten the bakelite, apply lubricating oil (3) replace the blade

Hands-on 5-5: How do I Change a blade?

2. The shaft does not turn and cannot be packed: (1) the cutter shaft is stuck with the cutter holder shaft or the foreign body is stuck; (2) the motor gear is loose or the starting capacitor or the motor is damaged.

Elimination method:

(1) Remove foreign matter and adjust cutter tension

(2) Tighten the motor gear or replace the starting capacitor or motor

Start 5-6: Change the tension spring set

(4) Filling part

1. Injection port leakage:

(1) The solenoid valve is blocked by foreign bodies and is not tightly closed

(2) Packaging board short circuit

Elimination method:

(1) Clean the solenoid valve blade film or replace the solenoid valve

(2) Change the packaging motherboard

Hands-on 5-7: Clean the solenoid valve and replace the solenoid valve.

2. Non-stop injection: (1) the water level probe is open (2) The packaging motherboard is out of control or there is leakage interference

Elimination methods: (1) Check the open part, clean the probe (2) motherboard water, plug open or thyristor short circuit, check the circuit to eliminate interference

Experiment 5-13: Disconnect the liquid level probe line and observe the phenomenon

3. Insufficient injection: (1) The filling valve air is not drained

(2) The injection pipeline is blocked by foreign matter or drug scale

(3) The small funnel is blocked

(4) The injection tube is too thin

(5) The injection position should be advanced

Elimination methods: (1) exhaust gas (2) Remove foreign matter and drug scale (3) Clean the small funnel (4) Change the φ8-φ10 pipe (5) to advance the injection position

Hands-on 5-8: How to change the solenoid valve?

Hands-on 5-9: How to clean Injection Nozzle? How to change the quick connector?

4. No injection: (1) The micro-switch is loose and fails (inside)

(2) Liquid level probe short circuit

(3) The thyristor is bad

Elimination method:

(1) Adjust or replace the microswitch

(2) Check the short circuit part and separate the probe

(3) Change the electric control board

Hands-on 5-10: Adjust or replace the microswitch

Experiment 5-14: Short-circuit the water level probe and observe

(5) Section packaging

1, the packaging machine segment packaging is not normal

(1) The sector is loose and fails

(2) Photocell damage, leakage or dirty - the fault of Chinese medicine pill making machine and troubleshooting methods

To learn more about our Fangyuan products, please click this link :https://www.fine-mill.com.

Our WhatsApp:+86 18115325508

Send Inquiry

whatsapp

Phone

VK

Inquiry