Fluid Bed Dryer Laboratory
Main Application
The fluid bed dryer laboratory is a commonly used laboratory equipment designed for drying, granulating, and coating solid particles. It operates on the principle of fluidization, where a bed of solid particles is suspended and behaves like a fluid when air or gas is passed through it. This promotes efficient drying and uniform heat distribution, making it suitable for various applications in laboratory settings.

Working Principle

Application
Fluid bed dryers are versatile laboratory equipment that find applications in various industries for drying, granulating, and coating solid materials. Here are some common applications of fluid bed dryers in laboratory settings:
Pharmaceutical Industry:
Drying of active pharmaceutical ingredients (APIs), excipients, and granules
Granulation of powders to improve flow properties and tablet manufacturing
Coating of tablets or granules for controlled release or taste masking
Food Industry:
Drying of food ingredients such as powders, granules, and herbs
Coating of food products with flavors, colors, or protective coatings
Granulation of food additives for improved handling and dispersion
Chemical Industry:
Drying of chemical powders, catalysts, and intermediates
Granulation of chemical compounds for easier handling and processing
Coating of particles for enhanced properties or functionality
Cosmetics Industry:
Drying of cosmetic powders, pigments, and additives
Granulation of cosmetic formulations for improved texture and performance
Coating of cosmetic particles for controlled release or aesthetic purposes
Research and Development:
Feasibility studies for new product formulations and processes
Optimization of drying parameters for specific materials
Scale-up studies to transition from laboratory-scale to production-scale operations
Materials Science:
Drying of polymers, resins, and composite materials
Granulation of materials for additive manufacturing or compounding
Coating of particles for functionalization or surface modification
Environmental Testing:
Drying of environmental samples for analysis
Granulation of materials for research on pollution control technologies
Coating of particles for environmental remediation applications
Academic Research:
Educational demonstrations on drying principles and applications
Research projects investigating drying kinetics and mechanisms
Collaboration with industry partners for innovative drying solutions
Technical Parameters
|
Model |
3 |
5 |
15 |
30 |
60 |
120 |
200 |
300 |
500 |
|
Container Volume(L) |
12 |
22 |
45 |
100 |
220 |
420 |
670 |
1000 |
1500 |
|
Container Diameter(L) |
300 |
400 |
550 |
700 |
1000 |
1200 |
1400 |
1600 |
1800 |
|
Capability Min(kg) |
1.5 |
4 |
10 |
15 |
30 |
80 |
100 |
150 |
250 |
|
Capability Max(kg) |
4.5 |
6 |
20 |
45 |
90 |
160 |
300 |
450 |
750 |
|
Fan Capacity |
1000 |
1200 |
1400 |
1800 |
3000 |
4500 |
6000 |
7000 |
8000 |
|
Fan Pressure(mm h2o) |
375 |
375 |
480 |
480 |
950 |
950 |
950 |
950 |
950 |
|
Fan Power(kw) |
3 |
4 |
5.5 |
7.5 |
11 |
18.5 |
22 |
30 |
45 |
|
Steam expenditure |
15 |
23 |
42 |
70 |
141 |
211 |
282 |
366 |
451 |
|
Comperessed air expenditure(m3/min) |
0.9 |
0.9 |
0.9 |
0.9 |
1.0 |
1.0 |
1.1 |
1.5 |
1.5 |
|
Weight of the main body(kg) |
500 |
700 |
900 |
1000 |
1100 |
1500 |
1500 |
1800 |
2000 |
|
Steam pressure(m3/min) |
0.3-0.6 |
||||||||
|
Temperature(.C) |
Adjustable at the range from room temperature to 120.C |
||||||||
|
Working time(min) |
Decided in accordance with the properties of raw materials. |
||||||||
|
Material yield |
>=99 |
||||||||
|
Noise |
When installation,main machine is separated from fan. |
||||||||
|
Dimension |
1.0*0.6*2.1 |
1.2*0.7*23 |
1.25*0.9*2.5 |
1.6*1.1*2.5 |
1.85*1.4*3 |
2.2*1.65*3.3 |
2.34*1.65*3.3 |
2.8*2.1*4.0 |
3*2.25*4.4 |
FAQ
1. Q : Can a fluid bed dryer laboratory be used for granulation or coating in addition to drying?
A: Yes, fluid bed dryers can be versatile machines that are capable of not only drying but also granulating and coating particles. By adjusting process parameters and introducing binders or coatings during fluidization, fluid bed dryers can perform multiple functions in a single operation.
2. Q : How do I choose the right fluid bed dryer for my laboratory needs?
A: When selecting a fluid bed dryer for laboratory use, consider factors such as the desired drying capacity, particle size distribution of the materials, required drying temperature, control system capabilities, and any additional features needed for specific applications such as granulation or coating.
3. Q : When we receive your machine ,is there any other Accessories we will get?
A: Yes,we will supply some tools for installation and maintenance.And some seal rings which you will need to replace during future normal use.
Hot Tags: fluid bed dryer laboratory, China fluid bed dryer laboratory manufacturers, suppliers, factory, Vibrating Flour Sifter, FBD Granulation, Double Z Blade Mixer, Strong Coarse Crusher, Pneumatic Liquid Paste Filling Machine, Fish Feed Pellet Dryer
Previous
Chemical Powder GranulatorYou Might Also Like
Send Inquiry